| To
protect dispensing systems each regulator has a built-in relief valve factory set to
relieve at 55-65 PSIG. Tap-Rite
secondary regulators are designed to further reduce pressure from a primary regulator to a
proper dispensing level.
Internal relief valve opens if the delivery
pressure exceeds set pressure by 15 PSIG. This serves as a warning that seat and/or
diaphragm may be worn and should be replaced.
Forged brass body for greater durability.
Body has enough mass to serve as a heat sink to help prevent freeze up problems.
Outlet fittings feature Tap-Rite's 1600 ball
type shut-off. Fits 5/16" I.D. pressure hose. Inlet is designed for
1/4" I.D. pressure tubing.
1/4" hose shut-off outlet fittings also
available. To order add -250 to part number. Inlet will be furnished with
1/4" I.D. hose nipple.
All models have heavy duty stainless steel
wall mounting brackets.
Maximum delivery pressure: 50 PSIG.
Non-removable adjusting screw limits maximum
delivery pressure to 50 PSIG.
Front loading seat assembly is easily
replaceable in the field. |